Precision Double Rockwell Hardness Tester-S3-JMHRS-150/45

Description:

S3-JMHRS-150/45 Precision Double Rockwell Hardness Tester (Movable nose). The advanced closed-loop sensor control technology is used to realize the automatic control and hardness testing process.
The loading system uses high precision force sensor and central controller to form a closed loop to realize continuous tracking and control of the loading process. High precision displacement sensor is used in Bathymetric system, and the resolution of minimum hardness is 0.1HR.
The loading table is fixed and the hardness is tested by moving the indenter up and down. Fixed test-bed can eliminate the coaxiality error caused by the up-down rotation of traditional lead screw, greatly improve the accuracy and repeatability of testing, and also increase the stability and efficiency of machine work.

Product Characteristics:
1. Fully automatic closed-loop sensor loading system, with fixed test bench, realizes high precision and fast testing, and also provides a higher level of standard hardness tester.
2. It can realize remote control.
3. Fifteen Rockwell hardness scales and 15 surface Rockwell hardness scales were tested.
4. The resolution of displacement sensor is 0.1HR.
5. The accuracy of repeatability is 0.5HR.
6. High-speed step control, very fast test speed (1.75s);
7. ASTM E18, ASTM E384, ISO6508 GB/T 230;
8. New design, mobile nose, strong frame structure, good rigidity;
9. The high precision loading system can effectively avoid the overload of force measurement.
10. High precision linear guideway controls the precise movement of the nose.
11. Continuous measurements can be made in and out of the fixed worktable through the automatic withdrawal function of the indenter.
12. The initial test force of the head of the automatic hoist and the automatic load can ensure the stable generation of the force.
13. High-definition LCD touch screen operation, menu operation interface;
14. Backlight LCD display, automatic data statistics and storage, RS-232 data output interface;
15. Automatic loading and unloading, adjustable loading time;
16. GO/NG tolerance judgment;
17. Correction of test values of cylinder and sphere;
18. Force selection and hardness scale selection are linked.
19. The optional operating languages include English and Chinese, which are convenient for users to operate.
20. Scale conversion HR, HB, HV;
21. Built-in printer;
22. The standard is fully equipped to meet the test requirements of all scales.

Technical Parameters
Model S3-JMHRS-150 S3-JMHRS-45 S3-JMHRS-150/45
Rockwell Initial Test Force 10kgf 3kgf 3kgf, 10kgf
Rockwell Initial Test Force 98.07N 29.4N 98.07N, 29.4N
Rockwell Total Test Force 60kgf、100kgf、150kgf 15kgf、30kgf、45kgf 60kgf、100kgf、150kgf
Rockwell Total Test Force 588.4N、980.7N、1471N 147.1N、294.2N、441.3N 147.1N、294.2N、441.3N、588.4N、1471N
Rockwell Scale HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRH, HRK, HRL, HRM, HRP, HRR, HRS, HRV HR15N, HR30N, HR45N, HR15T, HR30T, HR45T, HR15W, HR30W, HR45W, HR15X, HR30X, HR45X, HR15Y, HR30Y, HR45Y HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRH, HRK, HRL, HRM, HRP, HRR, HRS, HRV, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T, HR15W, HR30W, HR45W, HR15X, HR30X, HR45X, HR15Y, HR30Y, HR45Y
Testing Range HRA:20-95
HRB:10-100
HRC:10-70
HRD:40-77
HRE:70-100
HRF:60-100
HRG:30-94
HRH:80-100
HRK:40-100
HRL:50-115
HRM:50-115
HRR:50-115
HRP:50-115
HRS:50-115
HRV:50-115
HR15N:70-94
HR30N:42-86
HR45N:20-77
HR15T:67-93
HR30T:29-82
HR45T:10-72
HRA:20-95
HRB:10-100
HRC:10-70
HRD:40-77
HRE:70-100
HRF:60-100
HRG:30-94
HRH:80-100
HRK:40-100
HRL:50-115
HRM:50-115
HRR:50-115
HR15N:70-94
HR30N:42-86
HR45N:20-77
HR15T:67-93
HR30T:29-82
HR45T:10-72
Indenter specification Rockwell diamond indenter,Φ1.5875mm steel ball indenter
Executive standard ASTM E-18, ISO 6508, JJG 112, GB/T230
Conversion Scale HR, HB, HV, HK
Indication LCD Digital Display
Data Output Built-in printer, RS-232 interface
Maximum sample height 285mm
Distance from the center of indenter to body 175mm
Power Supply AC90-240V±5%/50-60Hz
Dimensions(L*W*H) 570*330*740
Machine net weight About 75kg